Product Name | OxytocinCYIQNCPLG - NH2 (Disulfide bridge: 1 - 6) |
Size | 25 mg |
Catalog # | AS-24276 |
US$ | $300 |
Purity | % Peak Area By HPLC ≥ 95% |
Oxytocin (OT) is a 9-amino acid peptide that is synthesized primarily in the hypothalamic neurons, specifically the magnocellular oxytocin neurons in the supraoptic and paraventricular nuclei and is secreted by the posterior pituitary gland. It is also secreted from other tissues, such as the ovaries and testes. Circulating OT is important during parturition and lactation. In the pregnant uterus, oxytocin and the oxytocin receptor play a major part for uterine contractility and the induction of labor. OT is also involved in complex social behaviors such as affiliation, sexual behavior, social recognition, stress buffering, aggression, and trust. | |
Detailed Information | DatasheetMaterial Safety Data Sheets (MSDS) |
Storage | -20°C |
References | Sabatier, N. et al. J Neurosci 23, 10351 (2003)Luck, M. et al. J Endocrinol 114, 423 (1987)Richter, O. et al. Arch Gynecol Obstet 269, 16 (2003)Hirst, J. et al. Endocrinol 124, 225 (1990)Szeto, A. et al. Psychosom Med (2012), doi: 10.1097/PSY.0b013e31821df0c2 |
Molecular Weight | 1007.2 |
CYIQNCPLG-NH2 (Disulfide bridge: 1-6) | |
Sequence(Three-Letter Code) | H - Cys - Tyr - Ile - Gln - Asn - Cys - Pro - Leu - Gly - NH2 (Disulfide bridge: 1 - 6) |
Product Citations | Beyer, C. et al. (2010).Angiotensin IV elevates oxytocin levels in the rat amygdala and produces anxiolytic-like activity through subsequent oxytocin receptor activation. Psychopharmacol 209, 303. |
ebiomall.com
>
>
>
>
>
>
>
>
>
>
>
具体应用是使用在:依据朗伯比尔定律(A=kbc)测定物质的吸光度A值,进行定量的目的。
可见分光光度计是有光源(钨丝灯发出连续光谱)、比色皿(装有色溶液)、单色器(给出单色光)、检测器(读出吸光度值)。
分光光度计已经成为现代分子生物实验室常规仪器。常用于核酸,蛋白定量以及细菌生长浓度的定量。
仪器主要由光源、单色器、样品室、检测器、信号处理器和显示与存储系统组成。
【1】光源:721型分光光计是钨灯;722型分光光度计是碘钨灯
【2】单色器:721型分光光计是棱镜;722型分光光度计是光栅
【3】检测器:721型分光光计是光电管;722型分光光度计是光电倍增管
【4】显示器:721型分光光计是表头指针读数;722型分光光度计是光电直读数据
可见分光光度计(又名可见光度计、分光光度计)是可见光分光光度法是上海美析仪器采用最新的单片机技术,开发出能够进行定量测量(标准曲线测量,可对物质进行浓度直读);OD值直接测量(吸光度、透过率和能量等直读);动力学测试(测出物质浓度随时间变化OD值的变化);光谱扫描(可以对某一种物质进行全波段扫描,分析物质的特征波长,判断实验过程的误差);多波长测试(可以对物质同时进行多个波长的测试,分析物质的相关特性);还有可以进行DNA/蛋白质测试、总磷总氮测试、重金属测试、农药残留测试、食品安全检测、热力发电金属离子测试等等,广泛应用于食品、药品、电力、生物研究、教学科研、化学化工、质量监督、水质环保和商检等各大领域。V-1500PC型可见分光光度计,波长范围:320nm-1100nm,能满足不同物质的测试。
紫外分光光度计测出来吸光度需要除以待测液的体积吗
本人新入植物化学,实验上遇到了一些问题,还望各位大神帮帮忙。
之前通过薄层色谱确定了最佳的展开剂以及展开剂的最佳比例,下一步将过硅胶柱。但是想通过将分光光度计与柱层析联用,将接收液直接进行紫外吸收,以此确定接收的液体为同一物质。但是现在遇到的问题是,在实验过程中是只需要用一种波长去测定还是要不停地调整?(现在只知道物质的极性,不知道组分中有哪些物质)
另外,是通过这种方法分离好一些还是过了柱子后再进行一次薄层色谱好一些呢?
各位大神帮帮忙,感激不尽!!!
暂无品牌问答