请使用支持JavaScript的浏览器! Estimation of Fat in Milk Samples_蚂蚁淘,【正品极速】生物医学科研用品轻松购|ebiomall -蚂蚁淘商城
当前位置: > 首页 > 技术文章 >
Estimation of Fat in Milk Samples
来自 : 蚂蚁淘

Introduction

Milkfatmeasurementisacommontaskinthedairyindustry,becausemilkfatcontentisonefactorthatdeterminesmilkpriceandisnecessarytoknowforcasein/fatrationormalization.Itisalsoimportantforthedairymantoknowmilkfatcontentexactly:discrepanciesintheresultsofmilkfattests(usuallyperformedinthedairyindustrialplant)haveeconomicrelevance.Inaddition,alowmilkfatcontentcouldindicatetheexistenceofanimalhealthdeficiencies.

Principle

Thefatcanbeseparatedfromfat-containingmilk/milkpowderthroughtheadditionofsulphuricacid.Theseparationismadebyusingamylalcoholandcentrifugation.Thefatcontentisreaddirectlyonaspecialcalibratedbutyrometeraftercentrifugation.

Apparatus

  1. Goodqualitybalance
  2. Specialbutyrometer
  3. Caoutchoucstoppers
  4. Pipettes-1and10ml
  5. Centrifuge,-1200rpm,equippedwithheatingelement

Reagents

  1. 90%Sulphuricacid
  2. 100%Amylalcohol

Procedure

  1. Mixthemilksample(temperatureabout20°C)thoroughly,takingcaretominimizeincorporationofair.Allowthesampletostandforafewminutestodischargeanyairbubbles.Mixgentlyagainbeforepipetting.
  2. Pipettesequentiallyintothebutyrometer:
    1. 10mlof90%sulphuricacid.
    2. 10.75mlmilk(mustnotbemixedwiththeacid).Note:Pipettetherequiredvolumeofmilkintothebutyrometer.Caremustbetakentoavoidcharringofthemilk,byensuringthatthemilkflowsgentlydowntheinsideofthebutyrometer.Itthenrestsontopoftheacid.
    3. 1mlamylalcohol
    4. somedropsofdistilledwater
  3. Cleantheneckofthebutyrometerwithatissueordrycloth.
  4. Closebutyrometerwithcaoutchoucstopperandshakuntilthemilkwasdissolved.Thebutyrometerwasturnedupside-down5ormoretimes.
  5. SpinintheGerbercentrifugefor15minutes.
  6. Thefatcolumnwasadjustedbyusingthestopper,sothatitwillbeinthegraduatedpartofthebutyrometer.Thefatpercentagewasreaddirectly.
  7. Note:Measurementsshouldbecarriedoutinduplicate.

Hazards

Sulphuricacidistoxic,highlycorrosiveandwillcausesevereburningifitcomesincontactwiththeskinoreyes.Whenmixingthebutyrometercontents,considerableheatisgenerated.

Ifthestopperisslightlyloose,leakagemayoccurduringmixing,centrifugingorholdinginthewaterbath.

Precautions

WearprotectiveeyegogglesAvoidallspillageanddroppingofsulphuricacidfromaciddispensers.Whenmixing,holdthebutyrometerstopperfirmlytoensurethatitcannotslip.Useaclothorglovetoprotectthehandswhenmixing.Donotpointthebutyrometeratanyonewhenmixing.

Authors**SanjeevSharma1,BRYadav1,AartiBhardwaj2,ShaliniJain3andHariomYadav31LivestockGenomeAnalysisLab,3AnimalBiochemistryDivision,NationalDairyResearchInstitute,Karnal-132001,India2MeerutInstituteofEngeeneringandTechnology,Meerut,U.P.,India

免责声明 本文仅代表作者个人观点,与本网无关。其创作性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不做任何保证或承诺,请读者仅作参考,并请自行核实相关内容。
版权声明 未经蚂蚁淘授权不得转载、摘编或利用其他方式使用上述作品。已经经本网授权使用作品的,应该授权范围内使用,并注明“来源:蚂蚁淘”。违反上述声明者,本网将追究其相关法律责任。