tech_banner
TriLink/NanoLink™ Streptavidin Magnetic Beads 1.0 μm/M-1002/2 mL at 10 mg/mL

Highest biotin-binding streptavidin magnetic beads on the market

Over the past 10 years, TriLinks streptavidin-coupled NanoLink™ Beads have been widely used in types of organizations and areregularlycited in papersfor diverse manual and automated applications.

NanoLink™ Streptavidin Magnetic Beads have the highest biotin-binding capacity on the market. Higher binding translates into reduced bead mass required to immobilize a biotinylated sample and lower background noise from nonspecific binding, resulting in better signals and lower net costs.

Download White Paper: How to Maximize the Capture of Biotinylated Targets with Streptavidin Magnetic Beads

NanoLink™ Outperforms Competitors on Free-Biotin Binding Capacity

The secret is in the crosslinkingNanoLink™ Streptavidin Magnetic Beads are 1.0micron-sized, super-paramagnetic, hydrophobic, and polyme–encapsulated (no exposed iron), with a fast (<2 min) magnetic response time. They are stable in colloidal form and in detergents. The key to high biotin binding is in the unique covalently crosslinked streptavidin, based onChromalink™ technology. The high surface area, when combined with our efficient linking chemistry, produces a consistent, ultra-high, biotin-binding bead. The high surface area and lower nonspecific binding makes NanoLink™ Steptavidin Magnetic Beads ideal for immobilizations and Co-IP applications.

NanoLink™ Binding Capacity vs. Competition

Ligand
NanoLink (1.0μm) Binding
Competitors 1 μm Bead Binding
Free biotin
>14 nmol/mg
>1,300 pmol/mg
Biotinylated oligo (23-mer)
>2.5 nmol/mg
NA
Biotinylated IgG (3 biotins per IgG)
>1.7 nmol/mg (250 μg/mg)
0.12 nmol/mg (20 μg/mg)

Advantages

  • Highest Biotin Binding – Supported by unique streptavidin crosslinking
  • Fast (<2 min) Response Time – Saves time and accommodates viscous samples
  • Versatile – NanoLink™ beads are ideal for immobilizations and Co-IP applications

Applications

  • Capture, immobilization, and separation of biotin-labeled biomolecules such as genomic DNA, RNA, PCR products, oligonucleotides, peptides, or antibodies. We recommend biotinylation with the ChromaLink™ Biotin Labeling Kit (Cat. No. B-9007-105K).
  • High-throughput robotic applications where high biotin-binding loads must be removed or immobilized without the presence of an iron leachate.
  • NanoLink™ Streptavidin Magnetic Beads are ideally suited for generating single-stranded PCR templates that can dramatically increase hybridization efficiency to complementary probes by removal of the unbiotinylated, competing PCR strand.

Additional Information

    • Product Insert and Protocol
    • Product Data Sheet
    • MSDS

Citations

  • Fowler DM, Araya CL, Fleishman SJ, Kellogg EH, Stephany JJ, Baker D, Fields S. High-resolution mapping of protein sequence-function relationships. Nature Methods 2010;7(9):741-6.Link
  • Kuzmin A, Poloukhtine A, Wolfert MA, Popik VV. Surface functionalization using catalyst-free azide-alkyne cycloaddition. Bioconjug Chem. 2010;21(11):2076-85.Link
  • Fan WQ, Morinaga H, Kim JJ, Bae E, Spann NJ, Heinz S, Glass CK, Olefsky JM. FoxO1 regulates Tlr4 inflammatory pathway signalling in macrophages. The EMBO Journal 2010;29(24):4223-36.Link
  • Branchini BR, Ablamsky DM, Rosenberg JC. Chemically modified firefly luciferase is an efficient source of near-infrared light. Bioconjug Chem. 2010;21(11):2023-30. Link
  • Mulligan EA, Hatchwell E, McCorkle SR, Dunn JJ. Differential binding of Escherichia coli McrA protein to DNA sequences that contain the dinucleotide m5CpG. Nucleic Acids Res. 2010 Apr;38(6):1997-2005.Link
  • Schreiber HA, Prechl J, Jiang H, Zozulya A, Fabry Z, Denes F, Sandor M.Using carbon magnetic nanoparticles to target, track, and manipulate dendritic cells.J Immunol Methods. 2010 Apr 30;356(1-2):47-59. Link
  • Jensen RB, Carreira A, Kowalczykowski SC. Purified human BRCA2 stimulates RAD51-mediated recombination. Nature 2010;467(7316):678-683.Link
  • Not for resale without express written permission. Not for use in humans. No license under any patent or patent pending is granted or implied by the purchase of any TriLink product. TriLink does not warrant that the use or sale of the products delivered hereunder will not infringe the claims of any United States or other patents or patents pending covering the use of the product alone or in combination with other products or in the operation of any process. All and any use of TriLink product is the purchaser’s sole responsibility.