产品说明
DescriptionReferencesDataQ & AManualS.D.SProduct DescriptionCell Counting Kit-8 (CCK-8) allows sensitive colorimetric assays for the determination of cell viability in cell proliferation and cytotoxicity assays. Dojindo’s highly water-soluble tetrazolium salt, WST-8, is reduced by dehydrogenase activities in cells to give a yellow-color formazan dye, which is soluble in the tissue culture media. The amount of the formazan dye, generated by the activities of dehydrogenases in cells, is directly proportional to the number of living cells. The detection sensitivity of CCK-8 is higher than the other tetrazolium salts such as MTT, XTT, MTS or WST-1.Cell viability detection mechanism with CCK-8ProcedureCell Counting Kit-8 requires 3 simple steps.The handling time of Cell Counting Kit-8 is the shortest among it’s competitors. Only 15 minutes of handling time for Cell Counting Kit-8 where as longer handling time is required for both MTS and MTT assay.StabilityCell Counting Kit-8 is a ready-to-use solution. It is also stabe at 4ºC for 1 year. Your assay can be done anytime without thaw and freeze.SensitivityCCK-8 (WST-8) is the highest sensitive dye for the cell based assay.Comparison of the sensitivity using tetrazolium dyeCytotoxicity of ReagentsOnly in CCK-8, continious culture is possible without killing cells.Observation of Cytotoxicity after incubation with each reagent.HeLa cells were incubated with WST-8 (CCK-8), WST-1, or MTS at 24 hours from addition of those reagents.Example Data using Cell Counting Kit-8Data for Cell Proliferation and Cytotoxicity AssayAbsorption property of WST-8The microplate reader with a 450-490 nm filter is applicable for the measurement.Absorption spectrum of WST-8 formazan dyeHow many cells should there be in a well?For adhesive cells, at least 1,000 cells are necessary per well (100 μl medium) when using a standard 96-well plate. For leukocytes, at least 2,500 cells are necessary per well (100 μl medium) because of low sensitivity. The recommended maximum number of cells per well for the 96-well plate is 25,000. If 24-well or 6-well plates are used for this assay, please calculate the number of cells per well accordingly, and adjust the volume of the CCK-8 solution in each well to 10% of the total volume.Can this kit be used with a 384-well plate?Yes, you can use this kit for a 384-well plate. Add CCK-8 solution with 1/10 volume of the culture medium in a well. If the volume of CCK-8 to be added is too small, dilute CCK-8 in half with the medium and add 1/5 of the volume of culture medium in a well.Can this kit be used with a 24-well plate?Yes. Add CCK-8 solution with 1/10 volume of the culture medium in a well.Does CCK-8 stain viable cells?No, it does not stain viable cells because a water-soluble tetrazolium salt (WST-8) is used for the CCK-8 solution. The electron mediator, 1-Methoxy PMS, receives electrons from viable cells and transfers the electrons to WST-8 in the culture medium. Since its formazan dye is also highly water soluble, CCK-8 cannot be utilized for cell staining.Does phenol red affect the assay?No. The absorption value of phenol red in culture medium can be removed by subtracting the absorption value of a blank solution from the absorption value of each well. Therefore, culture medium containing phenol red can be used for the CCK-8 assay.Is there a correlation between CCK-8 and the Thymidine incorporation assay?Yes. However, please note that since CCK-8 uses a different assay mechanism from that of the Thymidine assay, the results may differ. Comparison data are shown in the technical manual, which is available at www.dojindo.com/tm.Is CCK-8 toxic to cells?CCK-8 solution itself is cytotoxic because of the high concentration of 1-Methoxy PMS. CCK-8 in the culture medium, however, is not cytotoxic because of the ten times dilution with culture medium. Therefore, long incubation, such as overnight and several days, is possible. The same cell culture can be used for other cell proliferation assays, such as the crystal violet assay, neutral red assay, or DNA fluorometric assays after the CCK-8 assay is completed. Since each cell has a different tolerance to CCK-8, incubate cells with CCK-8 solution and check the cell viability if a longer incubation time is necessary.How stable is CCK-8?CCK-8 is stable over 6 months at room temperature and one year at 0-5 oC with protection from light. For longer storage, we recommend storing the solution at -20 oC ; CCK-8 is stable over 2 years at -20oC.I do not have a 450 nm filter. What other filters can I use?You can use filters with an absorbance between 450 nm and 490 nm.Related Categories Kits for Life Science Research
Dojindo细胞分析
细胞活力和细胞毒性测定用于药物筛选和化学物质的细胞毒性测试。Dojindo开发了高度水溶性的四唑盐,称为WST。WST-8是高度稳定的WST,用于Cell Counting Kit-8(CCK-8)。由于WST-8甲maz是水溶性的,因此不会形成晶体。因此,不需要诸如MTT测定的增溶过程。此外,CCK-8的检测灵敏度高于其他四唑盐,例如MTT,XTT,MTS或WST-1。
细胞增殖/细胞毒性转染细胞染色细胞内荧光探针细菌染色微生物活力测定干细胞分化SPiDER-ßGal线粒体检测细胞代谢
应用 | 产品展示 |
细胞生长检测,药物筛选,比色/荧光检测 | 细胞计数试剂盒-8 细胞计数试剂盒8 + 96孔有机硅定向剂 细胞计数试剂盒-F 细胞毒性LDH检测试剂盒 -WST 96孔有机硅定向剂 MTT |
了解检测机制的差异: | 点击这里 |
细胞周期分析 | 细胞周期测定溶液深红色 细胞周期测定溶液蓝色 |
文章排行榜
1
株式会社 同仁化学研究所
2
Blockade of L-type Ca2+ channel attenuates doxorubicin...
3
Systembio(SBI) Exosome-depleted FBS 去外泌体血清(无外泌体血清)
4
超氧化物歧化酶SOD活性检测试剂盒
5
让我们共同打造-“BIOSITE Triage®”主题活动(04-12-1)
6
绵羊、狗和SD大鼠的麻醉方法
7
众美生物代理品牌及产品线介绍
8
医院岗位绩效管理与成本精准管控课程通知
9
2008第十三届广州全国药品保健品展览会
10
2009医学前沿论坛暨第十一届全国肿瘤药理与化疗学术会议
微信公众号

手机扫码,关注动态