提醒:代购产品,无质量问题不接受退换货,下单前请仔细核对信息。下单后请及时联系客服 核对商品价格,订单生效后再付款。
biospec/Mini-Beadbeater-96/1/1001EUR
价格:

自营商城

解放采购

正品保障

及时交付

厂家直采

一站服务

货号:
品牌:
会员服务:
尊享会员价
贵宾专线
运费优惠
闪电退款
福利优惠
上门换新
友情提示
以上价格仅为参考,请联系客服询价。
免费咨询热线
4000-520-616
产品说明
Mini-Beadbeater-96The Mini-Beadbeater-96 is high-energy, high-throughput cell disrupter. It can process one 2 ml deep well micro plate (96 samples), two 1 ml deep well microplates (192 samples) or, using a included 45 capacity polypropylene microvial rack, 0.6, 1.5 or 2 ml microvials. In a busy day thousands of samples can be processed. Accessory 2 ml or 50 ml vial holders machined out of a solid aluminium blocks are availablle for strict temperature control, both at ice and liq N2 temperatures. See 'Features' tab, below, for more.Cat. No. 1001, Mini-Beadbeater-96, 115 volt.Cat. No. 1001EUR, Mini-Beadbeater-96, 230 volt.Beads and vials vary with the application and should be ordered separately. For selecting Beads and Vials see their links in Browse box in the left margin.Our Price : $0.00 Catalog Number Please choose catalog number 1001 1001EURItem requires freight shipping. Please call us at 800.617.3363 or 918.336.3363 to purchase.Call to Order Description Features Specifications Other Information The MiniBeadbeater-96 disrupts cells and tissue by violently shaking a sample inside a classic 2 ml microvial or standard deep well microplate partially filled with tiny ceramic or steel beads.  Complete cell disruption is achieved in 1 to 3 minutes of beadbeating.  A common application is nucleic acid extraction.  Up to 400 mg of tissue is added to a vial containing glass or ceramic beads and a nucleic acid extraction solution...the later often being purchased as part of a nucleic acid extraction kit.  The synergy of simultaneous mechanical cell disruption and nucleic acid extraction in a chaotropic solution gives very high yields of high quality RNA or DNA.  Most protocols developed using smaller capacity models of the MBB are transferable with little if any modification.The MiniBeadbeater can also be used for dry grinding. In this application, ceramic or steel beads are added to to vials containing hard, dry samples such as hair, bone, teeth, seeds and minerals. Softer materials such as biological tissue, rubber or plastics can be powdered by first pre-freezing the sample to liq N2 temperatures (called Cryo-grinding). Powdered material can be safely dissolved in an organic solvent in BioSpec's XXTuff microvials, our stainless steel microvials or Porvair's reinforced microplates, simplifying recovery of organic analytes. A solid aluminum vial holder can be utilized to maintain cryogenic temperatures during beadbeating (see the Accessories, below).Selected Applications Using the Mini-BeadbeaterHelpful Advice when Buying a Commercial High Through-put Cell DisrupterOPERATING INSTRUCTIONS:  See http://www.biospec.com/instructions/minibeadbeater_96/. Size 6 Color Magenta The MiniBeadbeater-96 is powered with a huge 1 hp induction motor.  No other beadbeater on the market offers higher shaking energies for cell disruption.  Power requirements for the 115 VAC MBB-96 is 20 amps, and for the 230 VAC machine it is 10 amps. Sample Capacity: Holds one 2 ml deep-well microplate or two 1 ml deep-well microplates.  Also included is a microplate shaped vial holder wich can hold 4 to 45 microvials (0.5, 1.5 & 2.0 ml) each containing up to 400 mg (wet weight) of biomaterial. Vial displacement distance or Throw: 1.25 in. (3.2 cm). Shaking Speed: Variable speed.  1400 rpm to 2400 rpm (40 oscillations/second). Disruption efficiency has been engineered for equivalency with other MiniBeadbeater models having smaller vial capacities - thus developed protocols are interchangeable.  The "calculated M/sec performance" value is greater than competitive beadbeater-type cell disrupters on the market. 3-D shaking pattern: Vial contents shake from the top to bottom of the vial or plate in a compressed figure-8 pattern.  Vials and microplates are held in a near-horizontal orientation rather than the less efficient vertical position.  This exclusive shaking pattern assures complete cell disruption in the shortest possible time.  No reorientation of plates in mid-cycle is required. Timer: 0 - 5 minutes with automatic reset. Recycle delay time: No motor cool-down time is required during or between sample runs. Dimensions: Width: 16 in, Depth: 24 in, Height: 18 in, 120 pounds Maintenance: None Warranty: Two years.IMPORTANT FEATURES AND CAPABILITIES►  COOLING. Temperature control must be addressed when using a bead mill cell disrupter for the isolation of proteins, membranes or organelles.  The Mini-BeadBeater-96, like all other high-energy, shaking-type bead mill cell disrupters, will heat up a sample from collisional friction of the beads...about 10° for each minute of beadbeating. An important accessory for the MBB-96 is a 48 capacity 2 ml microvial holder and a 2 tube capacity 50 ml tube holder, both machined out of solid aluminum.  Cooled beforehand in a deep freezer or with liquid nitrogen, the mass of the aluminum vial holder and its excellent heat transfer properties maintain samples at their initial low temperature during the entire beadbeating run...something that some competitor's bead mills offering flowing cold air accessories fail to accomplish.  The fact is that air is not an efficient media for the transfer and rapid removal of heat.  For this same reason, operating a bead mill cell disruptor in a cold room offers little regulation of heat buildup during beadbeating.But this is not always a concern.  Strict temperature control is not a needed when cells or tissue are being disrupted in the presence of DNA or RNA extraction media.►  ”DRY” GRINDING. The Mini-BeadBeater-96 can be used to powder most dried plant and animal tissues and, at  liquid nitrogen temperatures, fresh tissues. Exceptions to the rule are woody tissue and some tissues having high lipid or oil content.  Most dry grinding is done using steel beads.When dry- or cryo-grinding plant or animal tissue use our stainless steel microvials with silicone rubber caps, special XXTuff microvials or special Porvair Sciences deep well microplates. Common plastic microvials and deep well plates will break when dry grinding with steel beads.To the tubes or wells add either one 6.3 mm diameter chrome-steel bead, two 6.3 mm diameter zirconia beads or three 3.2 mm diameter chrome-steel beads.   Beadbeat for 5-30 seconds.  Note that steel beads can be used in common plastic vials and common deep well microvials for wet grinding, provided that the vial is completely filled with aqueous media and the amount of entrapped air is minimized..►  DEEP-WELL MICROPLATES. When using deep well microplates possible leakage and subsequent cross contamination between wells should be concern. While the entire mat surface area is evenly clamped to the microplate during beadbeating in the Mini-BeadBeater-96, the user must first thoroughly press the mat onto the microplate during the initial sealing process. Rollers and mat presses help in this task (see accessories listed below). The best mats are made of EVA or silicone rubber. Mats made of other rubber-like polymers or adhesive- or heat-bonded films - may not prevent leaking during the intense shaking in the Mini-BeadBeater-96.  There is an easy way to check for this concern.  Give us a call.►  SPEED CONTROL.  The Mini-BeadBeater-96 features digital variable speed control presets between 1400 rpm to 2400 rpm and three programmable time presets.  These presets allow for storage of your favorite speed and time settings for easy retrieval.SHOPPING GUIDELINES:  BioSpec Products was the first company to introduce bead mill cell disrupters to the scientific laboratory - some 30+ years ago.  This method of cell disruption of unicellular organisms and small tissue samples has superceded most traditional cell disruption methods.  In addition to BioSpec’s current five models of beadbeater cell disrupters, several other manufacturers now offer similar microvial-shaking, ‘beadbeater-type’ cell disrupters*.   Many of of these shakers fulfill the following physical parameters that assure maximum cell disruption performance: A SHAKING SPEED of at least 2000 rpm; a THROW or displacement of the vial of 3/4  to 1 inch, a FIGURE "8" SHAKING PATTERN and a NEAR HORZONTAL ORIENTATION of the vial, tube or microplate. The full incorporation of these parameters maximizes bead circulation and bead collisions within the vial.Side Note: Some, but not all, manufacturers are using shaking speed settings expressed as M/S..."meters/second".  A machine setting in m/sec is not a comprehensive measurement of cell disruption efficiency.  The term has caused buyer confusion while comparing cell disrupter bead-mill products.  The term also makes it difficult to reproduce cell disruption protocols when using a different bead mill cell disrupter. Because there is no consensus performance term for shaking-type bead mill cell disrupters BioSpec Products suggests that shaking cell disrupters machines be operated at their maximum available speed setting.  Beadbeater applications requiring lower operating speeds are rare.  Put bluntly, if the objective is to disrupt cells, crank up the rpm of the machine and get the job done.  The optimal time of beadbeating is a relevant varimable and will depend on the nature of the biological sample and the type of bead mill shaker used.  With current high performance machines, wet milling for 1-3 minutes gives close to 100% cell disruption.  If you are doing PCR work with nucleic acids and are content with less than 100% cell disruption, shorter periods of beadbeating will suffice.Besides the five variables shaking speed, vial throw distance, vial shaking pattern and orientation and time of shaking, three equally important variables which determine efficiency of cell disruption are bead size, bead composition and bead load in the vial.  These later three variables must be optimized by the user, not only for the particular ‘beadbeater’ machine being used, but for the type of sample being investigated."Solutions" to deal with these last three variables are being offered in the form of commercially available vials prefilled with beads.  Unfortunately, there is little comparitive literature documenting how these vendors came up with their "magic mixtures".One can usually get comparable results by loading your own beads into vials or microplates (and save a lot of money, too). Usually only one kind and size of bead will suffice.  Our Bead Selection Guidelines give a straight forward advice on how to select the correct bead size and composition and, if you have a lot of vials to load, BioSpec has three different bead loading devices designed to streamline the loading process.In addition to shaking-type bead mill cell disrupters there are also vortexing-type bead mill cell disrupters.  While the later will fulfill their intended goal, it can take 5 to 10X longer beadbeating times to get complete cell disruption.  The sole exception is BioSpec Product’s new SoniBeast™ cell disrupter, which uses patented high speed vortex technology to disrupt cells even faster than ordinary shaking-type beadbeating machines.You May Also Be Interested In...Leaf Tissue PunchLike a paper hole punch, the leaf tissue punch produces a single 1/4 inch diameter disc. The modified punch holds a standard snap-top or screw-top 2 ml microvial in a position to receive the sample without further touching or manipulation.Read more >Price: $26.00Deep Well Micro-plates and MatsMicroplates and sealing mats from Porvair Sciences.Cat. No. 2190302 ml Deep well Microplate, 50 plates per caseCat. No. 219004Sealing Mats, (fits 219030), 50 mats per caseRead more >Price: $248.00Vial Rack, Solid Aluminum, for 2 ml MicrovialsThis solid aluminum vial rack for 2ml vials offers superior temperature control during beadbeating than bead mill cell disrupters relying on flowing air chilled by dry-ice or refrigeration. It is well-known that chilled air has much poorer heat conductivity than chilled metal. The block is pre-cooled in a deep freezer or, to cryo-temperatures with dry-ice or liquid nitrogen. Having dimensions of a standard deep-well microplate, it is compatible with not only our MiniBeadbeater-96 but with several competitor microplate shakers.Read more >Price: $237.00Vial Rack, Polycarbonate, for 7 ml screw-cap tubesThis polycarbonate vial rack has a microplate footprint. It holds four to twelve 7 ml screw-cap vials (BioSpec's Cat No. 3205) and is used in our MiniBeadbeater-96 cell disruptor when larger-sized samples are being processed.Read more >Price: $43.00Vial Rack, Polypropylene, for 1.5 & 2 ml MicrovialsA pack of five polypropylene microvial vial racks. The rack has a standard microplate footprint and holds up to forty-five 1.5 ml or 2.0 ml microvials on one side and thirty-two 0.5 ml microvials on the other side. One of these racks comes standard with our Mini-BeadBeater-96.Read more >Price: $75.00Mat Roller1 1/2' rubber roller, for hand pressing mats onto microplates. Much easier than using your fingers but it is limited to low volume applications.Read more >Price: $38.0050 ml Tube Holder, Solid AluminumThis tube holder is machined out of a 1.5 lb aluminum block and has the dimensions of a standard 2ml deep well microplate. It is used with the MiniBeadbeater-96 cell disrupter. One or two 50 ml screw cap centrifuge tubes are placed completely inside the cold block and the contents shaken in the "wall to wall" direction. The block can be pre-cooled in a deep freezer or, at cryo-temperatures, with dry-ice or liquid nitrogen.Included with each vial block are 25 sterile, polypropylene 50 ml screw cap tubes (Stockwell brand, part # 3252).**Important note: To maximize the efficiency of heat transfer, this aluminum tube holder was designed to fit with close tolerance to the Stockwell-brand 50 ml tube. Other brands of 50 ml centrifuge tube may not fit properly. If you prefer to use a different brand tube, please check with us for compatibility.Read more >Price: $375.00

美国Biospec公司从事科学仪器近三十年,为许多实验室提供了高新的仪器设备,在组织研磨方面更是处于**地位。无泡沫,不产生气体,可以保持酶的活性,保护核酸和细胞器官,是进行PAGE,聚合酶实验和利用抗体或者寡核苷酸探针诊断的*佳仪器。这使我们能够以优惠的价格提供高品质的产品。

品牌分类
客服在线
service-logo
已有 人查看该问题
tel
全国免费服务热线
4000-520-616
微信公众号
关注我们
手机扫码,关注动态