Product DetailsRecommended AssayReferencesDescriptionCD19 is intended for in vitro diagnostic use in the identification of cells expressing CD19 antigen, using a BD FACS™ brand flow cytometer.The flow cytometer must be equipped to detect light scatter and the appropriate fluorescence, and be equipped with appropriate analysis software (such as BD CellQuest™ or BD LYSYS™ II software) for data acquisition and analysis. Refer to your instrument user’s guide for instructions.Format × FormatPE-Cy™7Excitation SourceBlue 488 nm,Green 532 nm,Yellow/Green 561 nmExcitation Max496nmEmission Max785nmPE-Cy™7 is a tandem fluorochrome that combines PE and a cyanine dye. PE-Cy7 conjugated reagents are as bright as PE conjugates. PE-Cy7 is particularly sensitive to photo-induced degradation, resulting in loss of fluorescence and changes in fluorescence spillover. Extreme caution must be taken to avoid light exposure and prolonged exposure to paraformaldehyde fixative. Fixed cells should be analyzed within 4 hours of fixation in paraformaldehyde or transferred to a paraformaldehyde-free buffer for overnight storage.Other Formats→FITCResources & ToolsSpectrum ViewerPanel DesignerSpectrumViewerDownload MSDSCFDA LicenseIFUPreparation and StorageThe antibody reagent is stable until the expiration date shown on the label when stored at 2° to 8°C. Do not use after the expiration date. Do not freeze the reagent or expose it to direct light during storage or incubation with cells. Keep the outside of the reagent vial dry.Do not use the reagent if you observe any change in appearance. Precipitation or discoloration indicates instability or deterioration.Clinical Applications of Flow Cytometry: Quality Assurance and Immunophenotyping of Lymphocytes: Approved Guideline. Wayne, PA: Clinical and Laboratory Standards Institute; 1998. NCCLS document H42-A.Protection of Laboratory Workers from Occupationally Acquired Infections–Second Edition; Approved Guideline. Villanova, PA: National Committee for Clinical Laboratory Standards; 2001. NCCLS document M29-A2.Cabezudo E, Carrara P, Morilla R, Matutes E. Quantitative analysis of CD79b, CD5 and CD19 in mature B-cell lymphoproliferative disorders. Haematologica. 1999;84:413-418.Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in health-care settings. MMWR. 1988;37:377-388.Dörken B, Möller P, Pezzutto A, Schwartz-Albiez R, Moldenhauer G. B-cell antigens: CD19. In: Knapp W, Dörken B, Gilks WR, et al, eds. Leucocyte Typing IV: White Cell Differentiation Antigens. New York, NY: Oxford University Press; 1989:34-36.Jackson AL, Warner NL. Preparation, staining, and analysis by flow cytometry of peripheral blood leukocytes. In: Rose NR, Friedman H, Fahey JL, eds. Manual of Clinical Laboratory Immunology. 3rd ed. Washington, DC: American Society for Microbiology; 1986:226-235.Loken MR, Shah VO, Dattilio KL, Civin CI. Flow cytometric analysis of human bone marrow. II. Normal B-lymphocyte development. Blood. 1987;70:1316-1324.Moldenhauer G, Dörken B, Schwartz R, Pezzutto A, Knops J, Hammerling GJ. Analysis of ten B lymphocyte-specific workshop monoclonal antibodies. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human B Lymphocytes. New York, NY: Springer-Verlag; 1986;2:61-67.Nadler LM. B Cell/Leukemia Panel Workshop: summary and comments. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human B Lymphocytes. New York, NY: Springer-Verlag; 1986;2:3-43.Reichert T, DeBruyère M, Deneys V, et al. Lymphocyte subset reference ranges in adult Caucasians. Clin Immunol Immunopath. 1991;60:190-208.Rothe G, Schmitz G. Consensus protocol for the flow cytometric immunophenotyping of hematopoietic malignancies. Leukemia. 1996;10:877-895.Stelzer GT, Marti G, Hurley A, McCoy P, Jr., Lovett EJ, Schwartz A. US-Canadian consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: standardization and validation of laboratory procedures. Cytometry. 1997;30:214-230.Tedder T, Zhou L-J, Engel P. The CD19/CD21 signal transduction complex of B lymphocytes. Immunol Today. 1994;15:437-442.
BD是世界上最大的生产和销售医疗设备、医疗系统和试剂的医疗技术公司之一。致力于提高全世界人类的健康水平。BD专注于改进药物治疗,提高传染性疾病诊断的质量和速度,推进新型药物和疫苗的研究与发现。BD公司具有强大的研发能力和世界上最棘手的多种疾病进行斗争的能力。公司于1897年在纽约成立,总部位于美国新泽西州的富兰克林湖,业务遍及全球。公司的业务可分为BD医疗、BD诊断、BD生物科学三大类,生产销售包括医用耗材、实验室仪器、抗体、试剂、诊断等产品。公司的服务对象包括医疗机构,生命科学研究所,临床实验室,工业单位和普通大众。
BD has state-of-the-art facilities around the globe that provide an environment that enables our highly talented workforce to be the best at their professions. We hire associates who have a passion and commitment to advancing the world of health. We are always seeking great people to join our company on its journey to greatness.
BD
Rat Granulocytes Pure RP-1 500ug |
|
|
550002 | BD | Ms Ig Kpa Lgt Chain FITC 187.1 500ug |
550007 | BD | ICC Fixation Buffer 100mL |
550011 | BD | Ms CD210 NALE 1B1.3a 500ug |
550019 | BD | Ms CD51 Pure RMV-7 100ug |
550026 | BD | Ms CD5 APC 53-7.3 100ug |
550037 | BD | Hu CD62E PE-Cy5 68-5H11 100Tst |
550041 | BD | Hu CD95 Pure EOS9.1 100ug |
550052 | BD | Ham IgG2 Kpa ItCl FITC B81-3 250ug |
550057 | BD | Ms Crry/p65 Pure 1F2 100ug |
550059 | BD | Ms IL-4 Recom Protein 10ug |
550068 | BD | Ms IL-2 Recom Protein 20ug |
550070 | BD | Hu IL-6 Recom Protein 10ug |
550072 | BD | Hu MIP-1 Bta PE D21-1351 100ug |
550082 | BD | Ms IgG1 PE A85-1 100ug |
550084 | BD | Ham IgG2 Kpa ItCl PE B81-3 100ug |
550086 | BD | Hu CD142 Pure HTF-1 100ug |
550254 | BD | Hu CD1d PE CD1d42 100Tst |
550256 | BD | Hu CD73 PE AD2 100Tst |
550258 | BD | Hu CD103 FITC Ber-ACT8 100Tst |
550260 | BD | Ms CD11c APC HL3 100ug |
550268 | BD | Ms CD72b/c Aloatg PE JY/93 100ug |
550270 | BD | Rat CD32 Pure D34-485 500ug |
550272 | BD | Rat CD32 NALE D34-485 500ug |
550274 | BD | Ms CD3e IHC Pure 145-2C11 1mL |
550277 | BD | Ms CD4 IHC Pure H129.19 1mL |
550280 | BD | Ms CD8a IHC Pure 53-6.7 1mL |